Skip to content

Partition wall (isometric) ​

About 7 min read

TwIsoPartitionWall · Category: Isometric equipment

Settings ​

These settings are in the properties panel on the right while the widget is selected. The default value is the value the widget has when it is first added to a page.

Geometry ​

SettingTypeDefaultDescription
Isometric axis
axis
SelectionxIsometric axis the equipment is aligned with. Switching between x and y turns the body 90° so its connections follow pipes on that axis.
Options: x, y
Mirror
mirror
CheckboxOffMirrors the equipment along its axis; left and right sides swap, including the connections.
Wall length
length
Number (1.5–16)4Wall length in grid units, 1.5–16. To close a corridor mouth, match the corridor width.
Door type
doorType
SelectionrollUpNone: plain wall. Roll-up (hangar) and high-speed doors follow Door opening; sliding and personnel doors follow Door open.
Options: none None, rollUp Roll-up (hangar), highSpeed High-speed PVC door, sliding Sliding, personnel Personnel door
Personnel door
personnelDoor
SelectionnoneAdds a separate personnel door next to the main door. Left/right are as seen by someone facing the wall from outside. It is not drawn if the wall is too short.
Options: none None, left Left, right Right
Door label
doorLabel
Text—Short text on the plate above the door, up to 12 characters. No plate is drawn when empty.
Floor depth behind
floorBack
Number (0–30)3Depth of the floor strip behind the wall (corridor side), 0–30. Match the corridor length to cover the whole corridor.
Floor depth in front
floorFront
Number (0–10)1.5Depth of the floor strip in front of the wall, 0–10.
Floor markings
floorMarking
CheckboxOnDraws yellow edge lines and a dashed walkway line along the door axis.
Panel wall color
wallColor
Color#e6eaecColor of the sandwich panel walls.
Floor color
floorColor
Color#a9b2b7Color of the floor strip.
Door color
doorColor
Color#8697a4Color of the door leaf or curtain.
Door open warning color
doorOpenColor
Color#f2a33aWhile the door is open, the door frame and the plate take this color.
Door control panel with stack light
doorPanel
CheckboxOffAdds a door control panel with a three-tier stack light on top (green bottom, yellow middle, red top): at the wall end left of the door on a cold room, right of the main door on a partition wall. Each lamp binds separately in the Door panel group: Off, Steady or Blinking; tag values 0/1/2 and Boolean on/off are accepted too. On a short partition wall the side personnel door goes first, then the panel.
RFID door gate
rfidGate
SelectionnoneFacing: two RFID readers on both door jambs facing each other. Each reader's connection, result and fault bind separately in the Readers group; the read field shows in the doorway, each half in its reader's color. On a cold room it is hidden with a cutaway front door; on a partition wall it is added to the main door, and if the wall is too short the side personnel door and then the gate are left out.
Options: none None, facing Facing (two readers)
Barcode reader at the door
gateBarcode
CheckboxOffAdds a barcode reader next to the door, aimed at the doorway.

Operation ​

SettingTypeDefaultDescription
Door opening (%)
doorPosition
Number (0–100)0Opening of the roll-up or high-speed door, 0–100. Bind it to a door position sensor; any value above 0 counts as open.
Door open
doorOpen
CheckboxOffShows the door as open; for example, bind it to a door switch tag. Roll-up and high-speed doors use Door opening instead.
Personnel door open
personnelDoorOpen
CheckboxOffShows the personnel door as open; for example, bind it to a door switch tag.
Play animation
play
CheckboxOnAllows animations such as rotation, belt movement and blinking. They also pause while the browser tab is hidden or the system asks for reduced motion.
Fault
fault
CheckboxOffFault state, usually bound to a tag. Shows a warning badge in the fault icon color; it blinks while the animation is on.
Fault icon color
faultColor
Color#e5484dColor of the fault warning badge.
Fault icon size (0.5–2×)
faultScale
Number (0.5–2)1Size of the fault badge, 0.5–2×. Room for the largest badge is always reserved, so the drawing does not shift.

Readers ​

SettingTypeDefaultDescription
RFID reader 1 connected
rfidConnected
CheckboxOnRFID reader communication state. When off the device is grey and dashed and its field is hidden.
RFID reader 1 read result
rfidResult
SelectionidleIdle, Reading, Good read, No read or Rejected (read but not allowed at this door or room). Tag values 0/1/2/3/4 are accepted in the same order.
Options: idle Idle, reading Reading, good Good read, noRead No read, rejected Rejected
RFID reader 1 fault
rfidFault
CheckboxOffRFID reader fault. Shows a red lamp and a blinking warning on the device.
RFID reader 2 connected
rfid2Connected
CheckboxOnCommunication state of the second RFID reader (below the lane on a read point, right of the door on a cold room). When off the device is grey and its field is hidden.
RFID reader 2 read result
rfid2Result
SelectionidleIdle, Reading, Good read, No read or Rejected (read but not allowed at this door or room). Tag values 0/1/2/3/4 are accepted in the same order.
Options: idle Idle, reading Reading, good Good read, noRead No read, rejected Rejected
RFID reader 2 fault
rfid2Fault
CheckboxOffFault of the second RFID reader. Shows a red lamp and a blinking warning on the device.
Barcode reader connected
barcodeConnected
CheckboxOnBarcode reader communication state. When off the device is grey and its field is hidden.
Barcode read result
barcodeResult
SelectionidleIdle, Reading, Good read, No read or Rejected (read but not allowed at this door or room). Tag values 0/1/2/3/4 are accepted in the same order.
Options: idle Idle, reading Reading, good Good read, noRead No read, rejected Rejected
Barcode reader fault
barcodeFault
CheckboxOffBarcode reader fault. Shows a red lamp and a blinking warning on the device.

Door panel ​

SettingTypeDefaultDescription
Red lamp
redState
SelectionoffState of the red lamp: Off, Steady on or Blinking. Blinking only animates while Play animation is on.
Options: off Off, on Steady on, blink Blinking
Yellow lamp
yellowState
SelectionoffState of the yellow lamp: Off, Steady on or Blinking. Blinking only animates while Play animation is on.
Options: off Off, on Steady on, blink Blinking
Green lamp
greenState
SelectionoffState of the green lamp: Off, Steady on or Blinking. Blinking only animates while Play animation is on.
Options: off Off, on Steady on, blink Blinking

Other settings ​

SettingTypeDefaultDescription
Enable Flashing
enableFlashing
CheckboxOffMakes the widget blink (an opacity pulse every second). Usually bound to an alarm condition.
Log Button
logButton
CheckboxOffAt runtime shows a chart icon when hovering the widget; clicking it adds the Tags bound to the widget to the log Tag list.

Bindings ​

In the Bindings (Rules) section of the properties panel, a Tag can be bound to the following properties of this widget with a Direct binding. The binding types (Direct, IntRange, FloatRange, Boolean, Bit) are the same for all widgets; they are described on the Widget Reference page.

title, visible, authorization, x, y, width, height, rotation, class, foregroundColor, backgroundColor, borderColor, borderStyle, borderWidth, borderRadius, borderTopLeftRadius, borderTopRightRadius, enableFlashing, logButton, fillColor, fillOpacity, strokeColor, strokeOpacity, strokeWidth, strokeDashArray, hoverColor, to.type, axis, mirror, play, fault, faultColor, faultScale, length, doorType, personnelDoor, doorLabel, floorBack, floorFront, floorMarking, wallColor, floorColor, doorColor, doorOpenColor, doorPosition, doorOpen, personnelDoorOpen, doorPanel, redState, yellowState, greenState, rfidGate, gateBarcode, rfidConnected, rfidResult, rfidFault, rfid2Connected, rfid2Result, rfid2Fault, barcodeConnected, barcodeResult, barcodeFault

Common sections ​

While this widget is selected, the properties panel also shows these common sections: General, Layout, Appearance, Drawing, Navigation (To), Bindings (Rules). These sections are described on the Page Editor page.

2WinScada 2.10