Skip to content

Downtime reason Pareto ​

About 3 min read

TwDowntimePareto · Category: Charts

Settings ​

These settings are in the properties panel on the right while the widget is selected, mostly in the Downtime Reason Pareto Settings section. The default value is the value the widget has when it is first added to a page.

Machines ​

SettingTypeDefaultDescription
Machines
seriesConfigJson
Series configuration[]Pick tags with a run/stop log (at most 20). The Pareto adds up the stops of all machines. Templates apply their tag prefix.
Group by
groupBy
SelectionreasonBars add up by reason or by category. Unclassified and micro-stop always stay separate bars.
Options: reason Reason, category Category

Time range ​

SettingTypeDefaultDescription
Time source
timeSource
Custom editorlocalLocal: the widget uses its own range. Page time: follows the page time picker; without a selection it falls back to its own range.
Range type
rangeMode
SelectionrelativeRolling window that ends now, or a calendar period (day, week, month, quarter, year).
Options: calendar Calendar, relative Relative
Calendar period
calendarPeriod
SelectiondayPeriod used when the range type is calendar.
Options: day Day, week Week, month Month, quarter Quarter, year Year
Window length (minutes)
timeRangeMinutes
Number1440Length of the rolling window in minutes. The server also limits the longest range (31 days when signed in).
Calendar offset
calendarOffset
Number00 is the current period, -1 the previous one. Future periods are not allowed.

Display ​

SettingTypeDefaultDescription
Maximum bars
maxBars
Number10Most bars shown (3–30). Further reasons are added up in an "Other reasons" bar.
Show unknown
showUnknown
CheckboxOnShows the time without data (unknown) in a separate tile; it is not counted as stop time.
Show export button
showExportButton
CheckboxOnShows an Excel button in the header. It downloads the Pareto on screen as .xlsx: the bars in display order (duration, stops, share, cumulative share), the totals and the machines, range and grouping. Disabled in the Editor preview.
Auto refresh (s)
autoRefreshSeconds
Number300While the range includes now the Pareto reloads at this interval. 0 turns it off; at least 60 seconds.
Cumulative line
showCumulativeLine
CheckboxOnShows the cumulative percentage as a line on a second axis.

Other settings ​

SettingTypeDefaultDescription
Enable Flashing
enableFlashing
CheckboxOffMakes the widget blink (an opacity pulse every second). Usually bound to an alarm condition.
Log Button
logButton
CheckboxOffAt runtime shows a chart icon when hovering the widget; clicking it adds the Tags bound to the widget to the log Tag list.

Bindings ​

In the Bindings (Rules) section of the properties panel, a Tag can be bound to the following properties of this widget with a Direct binding. The binding types (Direct, IntRange, FloatRange, Boolean, Bit) are the same for all widgets; they are described on the Widget Reference page.

title, visible, authorization, x, y, width, height, rotation, class, foregroundColor, backgroundColor, borderColor, borderStyle, borderWidth, borderRadius, borderTopLeftRadius, borderTopRightRadius, enableFlashing, logButton, downtimeParetoSchemaVersion, seriesConfigJson, timeSource, rangeMode, calendarPeriod, calendarOffset, timeRangeMinutes, groupBy, maxBars, showUnknown, showCumulativeLine, autoRefreshSeconds, showExportButton

Common sections ​

While this widget is selected, the properties panel also shows these common sections: General, Layout, Appearance, Bindings (Rules). These sections are described on the Page Editor page.

2WinScada 2.10